Saturday, October 17, 2026 · Edition updated 6:00 AM ETSAT, OCT 17 · 6 AM ET editionNext edition in Next --:--:--

Four dental splint materials wore down differently in a lab test

A study · BMC oral health · Oct 14, 2026

What this means

Researchers tested how much four splint materials wore away after chewing cycles in a lab. Wear differed by material, and the results cannot predict how long splints last in people.

Plain-English summary written by an AI model from the abstract. The original is below.

Tested inPeople
Who it was tested in
128 splint samples tested in a lab, not in people
Kind of research
A study

The science

Original title
Comparative volumetric wear of occlusal splint materials under simulated gastric acid and artificial saliva conditions.
Authors
Yıldız Domaniç K, Giritlioğlu Öztürk B, Ateş M
Journal
BMC oral health
Published
Oct 14, 2026
Study type
Study · in humans

Abstract

Background

Wear of occlusal splint materials may alter appliance geometry and occlusal relationships during use. This in vitro study evaluated the volumetric material loss of four commercially available occlusal splint materials differing in polymer composition and manufacturing technology after mechanical loading in artificial saliva and simulated gastric acid.

What they did

A total of 128 specimens were prepared from two digital light processing (DLP)-printed PMMA-based resins (Detax Freeprint Splint and Armarez), one CAD/CAM-milled PEEK material (PEEK Biosolution), and one conventionally injection-molded polyamide material (Cool&Flex). The specimens were allocated to artificial saliva or simulated gastric acid and subjected to either 30,000 or 120,000 chewing cycles. Baseline and post-simulation stereolithography datasets were superimposed, and volumetric material loss was calculated in mm³. The effects of material, storage medium, chewing-cycle number, and their interactions were evaluated using robust factorial ANOVA based on 20% trimmed means.

What they found

Volumetric material loss was significantly associated with material (p < 0.001, partial η² = 0.881), chewing-cycle number (p = 0.001, partial η² = 0.626), and the material × chewing-cycle interaction (p = 0.001, partial η² = 0.752). The main effect of storage medium was not statistically significant (p = 0.054). When values were pooled across both storage media and chewing-cycle conditions, Cool&Flex showed the greatest volumetric material loss (20% trimmed mean ± SE: 1.171 ± 0.193 mm³), whereas comparatively low values were observed for PEEK Biosolution (0.079 ± 0.014 mm³) and Armarez (0.087 ± 0.020 mm³). Under the conditions of this in vitro study, volumetric material loss differed among the tested commercial products and increased with mechanical loading, although the magnitude of this increase varied by material. Storage in simulated gastric acid did not significantly affect volumetric material loss. Because polymer composition and manufacturing method varied simultaneously among the products, their independent effects cannot be distinguished. These findings are limited to the materials and experimental conditions evaluated and should not be interpreted as direct predictions of clinical longevity.

The authors' abstract, grouped under plain headings from its own section labels.

Read it on PubMed ↗

Yıldız Domaniç K, Giritlioğlu Öztürk B, Ateş M Comparative volumetric wear of occlusal splint materials under simulated gastric acid and artificial saliva conditions. BMC oral health. 2026. doi:10.1186/s12903-026-10055-5. PMID: 42870261. https://pubmed.ncbi.nlm.nih.gov/42870261/

Report a problem